PRINTED IN UNITED STATES OF AMERICA
p/n 75844 Rev.D ECN-12851 M641 050712 cps
641
OWNERS MANUAL
for
E. B. C.™
Electronic
Brew
Control ™
DECANTER
COFFEE BREWERS
MODELS
1012
1040
1072
Includes:
Installation
Use & Care
Servicing Instructions
E.B.C.™ brewers are protected under
U. S. Patent # 5,704,275
Other U. S. and Canadian patents pending.
Models 1012 Brewer
with optional
8900-Series Glass Decanters
Model 1072 Brewer
with optional
8900-Series Glass Decanters
Vedere la pagina 0
1 2 3 4 5 6 ... 33 34

Sommario

Pagina 1 - Control ™

PRINTED IN UNITED STATES OF AMERICA p/n 75844 Rev.D ECN-12851

Pagina 2 - WARRANTY STATEMENT

8 OPERATION (continued) ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to the unit, all the lights will flash four times a

Pagina 3 - APPLICABILITY

OPERATION (continued) Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 17.

Pagina 4

10 BREWING COFFEE CAUTION: Burn Hazard Exposed surfaces of the brewer, brew chamber and decanter may be HOT to the touch, and can cause seriou

Pagina 5 - AGENCY LISTING INFORMATION

CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow br

Pagina 6 - INSTALLATION INSTRUCTIONS

TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power supply cord Check / reset circuit breaker Turn on and set for desired temperature. See p

Pagina 7

CAUTION ELECTRIC SHOCK HAZARD Live electrical circuits may be exposed while performing these procedures. These procedures are to be performed

Pagina 8 - OPERATION

SERVICING INSTRUCTIONS CAUTION Electric Shock Hazard Opening access panels or removing warmer plates on this brew may expose uninsulated electric

Pagina 9 - WATER FLOW

SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from

Pagina 10 - OPERATION (continued)

SERVICING INSTRUCTIONS (continued) IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure excee

Pagina 11

SERVICING INSTRUCTIONS (continued) 17 REPLACE SOLENOID Unplug power cord. Turn OFF and disconnect water supply from brewer inlet fitting. Remove fr

Pagina 12 - BREWING COFFEE

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Pagina 13 - CLEANING INSTRUCTIONS

REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove tank lid assembly

Pagina 14 - TROUBLESHOOTING SUGGESTIONS

SERVICING INSTRUCTIONS (continued) 19 Fig. 20 Keypad Ribbon Cable Hook-Up SET CONTROLLER JUMPERS Placing the jumper across Q

Pagina 15 - ERROR DETECTION

CAUTION - CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon de

Pagina 16 - SERVICING INSTRUCTIONS

7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then re

Pagina 17

EXPLODED VIEW & PARTS LIST CABINET COMPONENTS - IN-LINE BREWERS 22 641 75844 Owners Manual E.B.C. Decanter

Pagina 18

EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPTION USED ON 1 8700-16 Warmer

Pagina 19

EXPLODED VIEW & PARTS LIST (continued) CABINET COMPONENTS - LO-PROFILE BREWERS 24 641 75844 Owners Manual E.B.C. Decanter

Pagina 20

EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPTION USED ON 1 8700-16 Warmer

Pagina 21

EXPLODED VIEW & PARTS LIST (continued) HOT WATER TANK ASSEMBLY ITEM PART NO. DESCRIPTION

Pagina 22 - CHEMICAL BURN

ELECTRICAL COMPONENTS EXPLODED VIEW & PARTS LIST (continued) ITEM PART NO. DESCRIPTION

Pagina 23

TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consi

Pagina 24

EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS ITEM PART NO. DESCRIPTION

Pagina 25

WIRING DIAGRAM 29 641 75844 Owners Manual E.B.C. Decanter

Pagina 26

WIRING DIAGRAM p/n 75373 30 641 75844 Owners Manual E.B.C. Decanter

Pagina 27

WIRING DIAGRAM (continued) 31 641 75844 Owners Manual E.B.C. Decanter p/n 75361

Pagina 28 - HOT WATER TANK ASSEMBLY

PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:

Pagina 29 - ELECTRICAL COMPONENTS

FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls 2 641 75844 Owners Manual E.B.C. Decanter

Pagina 30 - INTERNAL PLUMBING COMPONENTS

PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qu

Pagina 31 - WIRING DIAGRAM

INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition

Pagina 32

INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with all applicable federal, state and local plumbin

Pagina 33 - WIRING DIAGRAM (continued)

OPERATION Fig. 4 Brewer Operation Diagram A. START-UP For initial start-up, or if the brewer has not been used for an extended

Pagina 34

OPERATION (continued) 7 WATER HEATER Water temperature is sensed by an electronic water temperature probe inserted into the water tank. This tempera