Bloomfield ELECTRONIC BREW CONTROL 1090 Specifiche

Navigare online o scaricare Specifiche per Caffettiera Bloomfield ELECTRONIC BREW CONTROL 1090. Bloomfield ELECTRONIC BREW CONTROL 1090 Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
PRINTED IN UNITED STATES OF AMERICA
p/n 75908 Rev. C ECN-12887 M645 050617cps
645
OWNERS MANUAL
for
E. B. C.™
Electronic
Brew
Control ™
DUAL
AIRPOT AND THERMAL
COFFEE BREWERS
MODELS
1090 1091
1092 1093
Includes:
Installation
Use & Care
Servicing Instructions
E.B.C.™ brewers are protected under
U. S. Patent # 5, 704,275
Other U. S. and Canadian patents pending.
Model 1092 Brewer
with optional
7759 Airpots
Vedere la pagina 0
1 2 3 4 5 6 ... 29 30

Sommario

Pagina 1 - Control ™

PRINTED IN UNITED STATES OF AMERICA p/n 75908 Rev. C ECN-12887

Pagina 2 - WARRANTY STATEMENT

8 OPERATION (continued) ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to the unit, all the lights will flash four times a

Pagina 3

OPERATION (continued) Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 19.

Pagina 4

BREWING COFFEE CAUTION: Burn Hazard Exposed surfaces of the brewer, brew chamber and airpot or server may be HOT to the touch, and can cause seri

Pagina 5 - AGENCY LISTING INFORMATION

CLEANING INSTRUCTIONS 11 PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow

Pagina 6 - INSTALLATION INSTRUCTIONS

TROUBLESHOOTING SUGGESTIONS 12 SUGGESTED REMEDY Check power supply cord Check / reset circuit breaker Turn on and set for desired temperature. Se

Pagina 7

CAUTION ELECTRIC SHOCK HAZARD Live electrical circuits may be exposed while performing these procedures. These procedures are to be performed

Pagina 8 - OPERATION

SERVICING INSTRUCTIONS CAUTION Electric Shock Hazard Opening access panels or removing warmer plates on this brew may expose uninsulated electric

Pagina 9 - WATER FLOW

SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Remove button plug from

Pagina 10 - OPERATION (continued)

SERVICING INSTRUCTIONS (continued) IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure excee

Pagina 11

SERVICING INSTRUCTIONS (continued) 17 REPLACE SOLENOID Unplug power cord. Turn OFF and disconnect water supply from brewer inlet fitting. Remove fr

Pagina 12 - BREWING COFFEE

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Pagina 13 - CLEANING INSTRUCTIONS

REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove tank lid assembly

Pagina 14 - TROUBLESHOOTING SUGGESTIONS

SERVICING INSTRUCTIONS (continued) 19 Fig. 19 Keypad Ribbon Cable Hook-Up SET CONTROLLER JUMPERS Placing the jumper across

Pagina 15 - ERROR DETECTION

CAUTION - CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon de

Pagina 16 - SERVICING INSTRUCTIONS

7. Set the tanks back into the brewer. Reassemble the tank lid to the tanks. Make sure the gasket is properly in place, then reinst

Pagina 17

EXPLODED VIEW & PARTS LIST HOT WATER TANK ASSEMBLY ITEM PART NO. DESCRIPTION USED

Pagina 18

ELECTRICAL COMPONENTS ITEM PART NO. DESCRIPTION USED ON 30

Pagina 19

EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS ITEM PART NO. DESCRIPTION

Pagina 20

EXPLODED VIEW & PARTS LIST (continued) CABINET COMPONENTS ITEM PART NO. DESCRIPTION

Pagina 21

WIRING DIAGRAM 26 MODEL VOLTS WATTS AMPS 1090 120/240 4000 17 1092 120/240 4000 17645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer

Pagina 22 - CHEMICAL BURN

WIRING DIAGRAM (continued) 27 E.B.C.™ BREWERMODEL VOLTS WATTS AMPS 1091 115/230 7000 30.5 1093 115/230 7000 30.5KEYPADKEYPADP1P11111CONTROLBOARDCO

Pagina 23

TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consi

Pagina 24 - HOT WATER TANK ASSEMBLY

PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:

Pagina 25 - ELECTRICAL COMPONENTS

FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls 2 645 75908 Owners Manual E.B.C. Dual Airpot/Thermal Brewer

Pagina 26 - INTERNAL PLUMBING COMPONENTS

PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qu

Pagina 27 - CABINET COMPONENTS

INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition

Pagina 28 - WIRING DIAGRAM

INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing co

Pagina 29 - E.B.C.™ BREWER

OPERATION 6 Fig. 4 Brewer Operation Diagram A. START-UP For initial start-up, or if the brewer has not been used for an extend

Pagina 30

OPERATION (continued) 7 WATER HEATER Water temperature is sensed by an electronic water temperature probe inserted into the water tank. This tempera

Commenti su questo manuale

Nessun commento