PRINTED IN UNITED STATES OF AMERICA
p/n 73573 Rev. V ECN-12817 M651 050208 cps
651
OWNERS MANUAL
for
E-Max™
DECANTER
COFFEE BREWERS
MODELS
2012
2016 2016EX
2072 2072L
2072FR 2072FRL
2074 2074L
2074FR 2074FRL
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 2012
3-Warmer
In-Line Brewer
with optional
8900 Decanters
E-Max BREWERS are covered under
U. S. Patents #5704275, 5862738, 6095031.
Other U.S. Patents and Canadian Patents Pending
Model 2072FR
Filter-Ready 3-Warmer
Step-Up Brewer
with optional
8900 Decanters
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - 0208 cps

PRINTED IN UNITED STATES OF AMERICA p/n 73573 Rev. V ECN-12817

Pagina 2 - WARRANTY STATEMENT

PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water temperature on the screen, the E-Max™ brewer must be

Pagina 3 - SPECIFICATIONS

8. Clock A. Time – Battery Backup. The E-Max™ has a battery backup system which will maintain the proper time during power

Pagina 4

OPERATION (continued) 12. View Filter Statistics: To view filter statistics, turn the brewer off. Press and hold the 1st key (Brew), and

Pagina 5

CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow br

Pagina 6 - INSTALLATION INSTRUCTIONS

FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller.

Pagina 7 - STRAINER

SERVICING INSTRUCTIONS — PLUMBING (continued) 13 ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2012, 20722015, 2075 6

Pagina 8 - OPERATING INSTRUCTIONS

SERVICING INSTRUCTIONS - ELECTRICAL FUNCTION 1. Pressing the POWER key energizes the unit. The POWER LED will glow whenever the unit is ON. 2. A

Pagina 9 - Brew complete

SERVICING INSTRUCTIONS - ELECTRICAL (continued) 15 ITEM DESCRIPTION PART N0. USED ON 3 PROBE, TEMPERATURE 83480 ALL 4 THERMOSTAT, HI-LIMIT SAFETY (1

Pagina 10 - OPERATION (continued)

SERVICING INSTRUCTIONS — DE-LIMING WATER HEATER TANK 1. Disconnect brewer form the electrical supply. Turn off the water supply and disco

Pagina 11

TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below, it will likely be necessary to reset the brewer in o

Pagina 12

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Pagina 13 - CLEANING INSTRUCTIONS

EXPLODED VIEW & PARTS LIST 18 3-WARMER IN-LINE BREWER MODELS: 2012, 2016

Pagina 14 - LID GASKET

EXPLODED VIEW & PARTS LIST (continued) 19

Pagina 15

EXPLODED VIEW & PARTS LIST (continued) 20 3-WARMER STEP-UP BREWER MODELS: 2072, 2074

Pagina 16 - WARNING:

EXPLODED VIEW & PARTS LIST (continued) 21

Pagina 17

WIRING DIAGRAMS White #11White #11White #10Red #6Black #9Black #9Brown #1#1#2#3WhiteWhiteWhite #11Red #4RedBlueBlue #5Orange #3Orange #7Orange #8Red #

Pagina 18

WIRING DIAGRAMS (continued) 23 Black #16Orange #3Blue #7Black #8Red #141234Red #6Brown #1Blue #2Black #9White #12White #10White #11Tank Heater3200 Wat

Pagina 19 - TROUBLESHOOTING SUGGESTIONS

WIRING DIAGRAMS (continued) 24 IN-LINE BREWER 240 VOLT

Pagina 21

PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:

Pagina 22 - MODELS: 2072, 2074

TABLE OF CONTENTS SPECIFICATIONS Thank You for purchasing this Bloomfield Industries appliance. Proper installation, professional operation and consi

Pagina 23

FEATURES AND OPERATING CONTROLS 2

Pagina 24 - WIRING DIAGRAMS

WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not o

Pagina 25 - WIRING DIAGRAMS (continued)

INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspect all

Pagina 26

INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes

Pagina 27

OPERATION IMPORTANT: All E-Max™ brewers are tested and set at the factory. If programming adjust-ments are necessary, refer to the E-Max™ Progr

Pagina 28

OPERATION (continued) WARNING: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury f

Commenti su questo manuale